====== [SOILDATA] Section ====== ===== Purpose ===== This sections sets the initial temperature and humidity profile for the soil and the surfaces in the model.\\ The temperature and the humidity settings are divided into 3 layers. 00: [SOILDATA] _______________________Settings for Soil 01: Initial Temperature Upper Layer (0-20 cm) [K]=293 02: Initial Temperature Middle Layer (20-50 cm) [K]=293 03: Initial Temperature Deep Layer (below 50 cm)[K]=293 04: Relative Humidity Upper Layer (0-20 cm) =50 05: Relative Humidity Middle Layer (20-50 cm) =60 06: Relative Humidity Deep Layer (below 50 cm) =60 ===== What do the lines mean? ===== === 01,02,03: Initial Temperature Surface/ Soil (Default: 293K all)=== Start temperature for the soil and the surface for the 3 soil layers.\\ The deep soil temperature (-2.00 m) is kept constant during simulation. === 04,05,06: Relative Soil Humidity (Default 50,60,60%) === The humidity value is calculated using the water content at **field capacity** value to get the start water content.\\ The value should not be lower than 10%, otherwise the possibility of numerical problems rise.\\ For sealed material, the soil humidity is automatically set to zero. \\ \\ ===== ===== **Compatibility remark - important**\\ V4.0 and higher now relates the relative humidity to the __field capacity__. Up to V3.0 it was related to the saturation value.\\ Please note, that Version 3.1 and newer do no longer support the old ''[SOIL]'' section which is obsolete since V2.5.